Bunn SRU Coffeemaker User Manual


 
Page 8
PROBLEM
Brew cycle will not start
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage to
the brewer
REMEDY
Water lines and valves to the brewer
must be open.
(A1) Check the terminal block for
120 volts ac across the red and
white terminals and the black and
white terminal on three wire 102/
208 volt or 120/240 volt models.
(A2) Check the terminal block for
208 volts ac, 230 volts ac or 240
volts ac on "A Series" brewers across
the red and black terminals on two
wire single phase 208 volt, 230 volt
and 240 volt models.
(A3) Check the terminal block for
208 volts ac and 240 volts ac across
the black and blue terminals, the
blue and red and the black and red
terminals on three wire three phase
208 volt and 240 volt models.
(B) Check circuit breakers or fuses.
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times. Keep away from combustibles.
WARNING Exercise extreme caution when servicing electrical equipment.
Unplug the brewer when servicing, except when electrical tests are specified.
Follow recommended service procedures
Replace all protective shields or safety notices
10067 040100