Bunn ULTRA-2 Coffee Grinder User Manual


 
14
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
• Inspection,testing,andrepairofelectricalequipmentshouldbeperformedonlybyqualiedserviceperson-
nel.
• Allelectroniccomponentshave120voltacand/orlowvoltagedcpotentialontheirterminals.Shortingof
terminals or the application of external voltages may result in board failure.
• Intermittentoperationofelectroniccircuitboardsisunlikely.Boardfailurewillnormallybepermanent.If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
• Keepawayfromcombustibles.
WARNING – • Exerciseextremecautionwhenservicingelectricalequipment.
• Unplugthedispenserwhenservicing,exceptwhenelectricaltestsarespecied.
• Followrecommendedserviceprocedures
• Replaceallprotectiveshieldsorsafetynotices
No Power
Correct voltage
at outlet?
No Yes
Call licensed
electrician for repair
12vac to Control Board
at J5-8 & J5-20?
Yes No
Does Membrane
Switch test ok?
Yes
No
Replace Membrane
Switch
Replace Control
Board
12vac from secondary
of transformer?
No
Yes
Replace
Transformer
Check main
wiring harness
41084 102709