Cleveland Range Gas 20.20 Convection Oven User Manual


 
-U20:X2:3
-U20:X2:4
-U20:X2:2
/5.C6
X27:
8
12
11
10
9
-A20
3
7
6
5
4
2
1
HEAT REQUEST
3
10 912 11 365487
12345678
GAS BOARD
GM5010
X26:
RECIEVE
TRANSMIT
12V
GND
12VDC IN
0VDC IN
RxD_12V
TxD_12V
1324
GND
RESET
X28:
576 8
9
STEAM GEN 1 FLAME OK
GND. FIRING AUTOMAT
CONVECTIO 1 FLAME OK
X25:
11 91012
13265487
12
X20:
ALARM
ALARM
HEAT REQUEST
RESET
RESET
PHASE ( L1 )
21354687
9
X24:
SPEED STEAM GENERATOR
PWM STEAM GENERATOR
GROUND STEAM GENERATOR
RESET
RESET
10
12
GROUND HOT AIR 1
PWM HOT AIR 1
SPEED HOT AIR 1
231564
ALARM
ALARM
X21:
45 768
9
1
2
3
X23:
X22:
6
4
5
7
8
9
/2.C8
/2.C8
/2.C8
/2.C8
/2.C5
/2.C5
/2.C5
/2.C5
/7.C3
/5.C3
/2.A6
/2.A7
/2.A6
/7.C6
-U10.2:RxD
-X13.7:1
-U10.2:TxD
-U10.2:12V
-U10.2:COM
-U10.1:RxD
-U10.1:TxD
-U10.1:12V
-U10.1:COM
-N22:X1:2
-N20:X1:2
-U22:X2:2
-U22:X2:4
-U22:X2:3
-N22:X1:1
-N20:X1:1
46
-X10
/5.C3
/7.C3
-A10:X10:5
-A10:X10:8
-A10:X10:6
-A10:X10:7
/3.D4
/3.D4
/3.D4
/2.D3
/2.E2
-G1:0V
-G1:12V
/3.D4
RD 18
/5.C4
-N20:X1:10
-N20:X1:5
/5.C4
/5.C4
/3.D5
-X10
40
-N20:X1:11
-X10:33
41
RECIEVE
TRANSMIT
12V
GND
-N22:X1:11
/7.C4
RD 18
RD 18
RD 18
RD 18
-X10
44
45
/7.C4
-N22:X1:5
-N22:X1:10
/7.C4
-X13.7:3
-X13.7:2
/7.C7
/7.C7
/5.C7
/5.C7
RD 18
RD 18
RD 18
RD 18
RD 18
RD 18
RD 18
RD 18
RESET
RESET
HEAT REQUEST
ALARM
ALARM
HOT AIR 2
(HL2)
HOT AIR 1
(HL1)
STEAM GEN.
(DE)
GROUND HOT AIR 2
PWM HOT AIR 2
SPEED HOT AIR 2
MOTOR SPEED M2
12v(FOR SENSOR)
SENSOR GND M2
F
E
D
C
B
A
12345678
F
E
D
C
B
A
12345678
CLEVELAND RANGE, LLC
1333 East 179th St., Cleveland, Ohio 44110-2574
VOLTAGE:
WATTAGE:
CURRENT:
DATE
SHEET OF
REV
DRAWN BY
DRAWING NO.
THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.
TITLE
SIZE
B
WIRING DIAGRAM
OGS 20.20
300498
110-120
-
22.5A
DRL
12-02-05
49
A
WIRING DIAGRAM
CONVECTIO 2 FLAME OK
68