Crane Merchandising Systems 675 Beverage Dispenser User Manual


 
Test the Machine HDC II Programming Guide
6730018 67 July, 2003
VIEW SUREVEND™ AVERAGE CALIBRATION
VALUE
1. Press , then press until the display shows .
XXX represents the average sensor calibration value (should be between 50
and 255 for proper sensor operation - i.e. 51 through 254). Although this
number could go as low as 20, the SureVend™ system will be inoperative
in this condition.
2. CONTINUE.
CLEAR TANK ERRORS AND FILL THE TANK
1. Press , then press until the display shows .
2. Press . This clears any tank error and starts filling the tank, if neces-
sary. If it is taking a long time to fill the tank AND THERE ARE NO
LEAKS, you may see
in the diagnostic list again. Just press
again after making sure there are no other problems, such as a
restriction in the water inlet line or a clogged water filter.
3. CONTINUE.
TEST THE DISPLAY
1. Press , then press until the display shows . The
"DRINK BEING SERVED" lamp is lighted (if so equipped), and remains
lighted until you leave this function.
2. Press to light all display segments; press to turn them off.
3. Pressing a NUMBER KEY on the control panel causes all segments to dis-
play that character.
4. CONTINUE.