Electrolux EIKG5546 Electric Pressure Cooker User Manual


 
A spirit level should be placed on one of the
shelves to confirm the appliance is correctly
levelled.
Connecting to the electricity supply
Warning! This appliance must be
earthed. Do not earth this appliance to
the gas supply piping. Connect to 230 -
240V AC supply only.
Connection to the electricity supply should
be made via a properly earthed, readily ac-
cessible wall socket. Which is adjacent to,
but not directly above and not more than
1.7m away from the appliance and capable
of electrical isolation.
The cooker point should be within 1.7m of
the appliance to make it accessible to switch
off the appliance in case of emergency.
The mains lead should be routed so that it
cannot touch hot parts of the cooker i.e. the
back panel above a height of 650mm from
the floor. Should this plug not fit the socket
outlet in your home it should be cut off and
replaced with a suitable plug as outlined be-
low.
If the supply cord is damaged, it must be re-
placed. Please contact your local Service
Force Centre.
If the moulded plug is cut from the cable for
any reason it must be destroyed or disposed
of safely, as protruding wires will be an elec-
trical shock hazard.
If the fitted plug is removed.
The flexible mains lead must be correctly
connected as below to three pin plug of not
less than 13amp capacity.
If a B.S. 1363 fused plug is used, it must be
fitted with a 3 amp fuse which is approved to
B.S. 1362.
Important: The wires in the mains lead
fitted to the appliance are coloured in
accordance with the following code.
GREEN AND YELLOW = EARTH
•BLUE = NEUTRAL
•BROWN = LIVE
As the colours of the wires in the mains lead
of this appliance may not correspond with
the coloured markings identifying the termi-
nals in your plug, proceed as follows:-
The wire which is coloured green and yellow
must be connected to the terminals in the
plug which is marked with the letter E or by
the earth symbol (
) or coloured green or
green and yellow.
The wire which is coloured blue, must be
connected to the terminal which is marked
with the letter N or coloured black.
The wire which is coloured brown, must be
connected to the terminal, which is marked
with the letter L or coloured red.
Ensure that the cable does not become trap-
ped when pushing the appliance into posi-
tion.
If a moulded plug is fitted.
In the event of replacing a fuse in the plug
supplied a 3 amp ASTA approved fuse to
B.S. 1362 must be fitted.
Note: The fuse cover must be refitted
when changing the fuse.
In the event of losing the fuse cover the plug
must not be used until a replacement fuse
cover has been obtained and fitted.
Connecting to the gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R3/8.
Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just be-
low the hotplate level on the rear left hand
side of the appliance.
NOTE: ONLY LIQUID SEALANTS TO
BE USED WHEN INLET GAS PIPE IS
FITTED I.E.: DO NOT USE P.T.F.E.
SEALANT TAPE.
22 electrolux