Loading info : Gas hob
Natural Gas R.H.F R.H.R L.H.R L.H.F
Heat input 1.0kW (3412 Btu/
h)
1.9kW (6483 Btu/
h)
1.9kW (6483 Btu/
h)
3.4kW (11600
Btu/h)
Injector Marking 070 096 096 136
L.P. Gas R.H.F R.H.R L.H.R L.H.F
Heat input 1.0kW 2.0kW 2.0kW 3.4kW
Injector Marking 050 (71.8g/h) 071 (136.5g/h) 071 (136.5g/h) 093 (244.12g/h)
Loading info : Grill
Natural Gas L.P. Gas
Heat input 2.7kW (9212Btu/h) 2.7kW (194g/h)
Injector Marking 120 95
Loading info : Top oven
Natural Gas L.P. Gas
Heat input 1.9kW (6483 Btu/h) 1.9kW (136.5g/h)
Injector Marking 099 070
Dual control by-pass marking 50 38
Loading info : Main oven
Natural Gas L.P. Gas
Heat input 1.9kW (6483 Btu/h) 1.9kW (136.5g/h)
Injector Marking 099 070
Thermostat by-pass marking 75 80
General
Ignition (H.T. Spark)
Spark Gap 3-4mm
GAS CATERGORY COUNTRIES OF DESTINATION
CAT. I
2
H GB, IE
CAT. I
3
+ GB, IE