70
Electrical Connection
The oven is designed to be connected to 230-240V~(50Hz) electricity
supply.
The oven has an easily accessible terminal block which is marked as
follows:
1 This oven must be earthed!
The cable used to connect the oven to the electrical supply must
comply to the specifications given below.
For UK use only
It is necessary that you install a double pole switch between the oven and
the electricity supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type suitable for the required load in
compliance with the current regulations.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot
at any point reach a temperature of more than 50°C above the ambient tem-
perature.
Before the oven is connected, check that the main fuse and the domestic
installation can support the load; and that the power supply is properly
earthed.
The manufacturer declines any responsibility should these safety
measures not be carried out.
Letter L - Live terminal
Letter N - Neutral terminal
E - Earth terminal
Connection
via
Min. size
Cable/flex
Cable/flex
type
Fuse
• 13 A
socket outlet
• 13 A
spur box
2,5 mm
2
3 core butyl
insulated
13 A min.
• Cooker Control
Circuit
2,5 mm
2
PVC/PVC
twin and earth
15 A min.
20 A max.