11
Installation instructions
Converting to a different gas type
This appliance is suitable for use with Natural gas or Propane gas (check the “gas type”
sticker attached to the appliance). To convert from one gas type to another, you need to
replace the injectors, and then adjust the minimum burning setting.
To replace the injectors
Remove pan supports and burners from the cooktop.
Using a spanner, remove the injector (shown in Fig.s following) and replace it with one
according to the gas type (see the ‘Table for the choice of injectors’).
Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the
gas inlet connections. This label states that the gas cooktop has been converted for use
with Propane gas / Natural gas.
Important!
If the cooker is suitable for use with Natural gas and must be converted for use with
Propane gas, before connecting to gas main remove the appliance gas regulator and replace
with test point adaptor.
If the cooker is suitable for use with Propane gas and must be converted for use with
Natural gas, before connecting to the gas main remove the appliance test point adaptor and
replace with gas regulator.
Notes:
- Gas regulator and test point adaptor are supplied with the appliance (packed with the
conversion kit).
- The burners are designed so that regulation of primary air is not required.
Fig. 9 Auxiliary and semi-rapid burners
Fig. 10 Triple ring wok burner
Injector
Injector