Installation instructions
Clearances
Installation clearances and protection of combustible surfaces shall comply with the current
local regulations eg. AG 601 (AS 5601) Gas Installations code. Installation shall comply with
the dimension in Fig. 1 bearing in mind that:
Overhead Clearances
In no case shall the clearances above the highest part of the cooker be less than 600
mm or, for an overhead exhaust fan, 750 mm. AII other downward facing combustible
surfaces less than 600 mm above the cooker surface shall be protected for the full width
of the cooking surface in accordance with the standards noted above. In no case shall the
clearance be less than 450 mm.
Rear and Side Clearances
Where the distance from the periphery of the nearest burner to any vertical combustible
surface is less than 200 mm, the surface shall be protected in accordance with the
standards to a height of not less than 150 mm above the cooking surface for the full
width or depth of the cooking surface. Where the distance from the periphery of the
nearest burner to any horizontal combustible surface is less than 200 mm, the horizontal
surface shall be more than 10 mm below the surface of the hob, or the horizontal surface
requirement above.
Protection of combustible surfaces
The standards above specify that, where required, protection shall ensure that the surface
temperature of the combustible surface does not exceed 65°C above room temperature. Do
not install the cooker near flammable materials (eg curtains). If you stand the cooker on a
pedestal, make sure you provide safety measures to keep it in place.
Fig. 1 Dimensions and correct
distances from cooker
105 mm
500 mm
450 mm
750 mm
Cooker overall dimensions [mm]
• height: min 900 - max 915
• width: 600
• depth: 600