Fisher & Paykel OR60 Electric Pressure Cooker User Manual


 
12
Regulation screw
Installation instructions
Adjusting the minimum burner setting
Check whether the flame spreads to all burner ports when the burner is lit with the gas
tap set to the minimum position. If some ports do not light, increase the minimum gas rate
setting.
Check whether the burner remains lit even when the gas tap is turned quickly from
the maximum to the minimum position. If the burner does not remain lit, increase the
minimum gas rate setting.
To adjust the minimum gas rate setting:
Turn on the burner.
Turn the tap to the MINIMUM position.
Take off the knob.
Using a small flat screwdriver, turn the screw to the correct regulation.
Note: for Propane gas, the regulation screw is normally tightened up.
Fig.11 Adjusting the minimum burner setting
Table for the choice of injectors
Natural gas Propane gas
Test Point Pressure [kPa]
1.0 2.75
BURNER
Injector
Ori ce Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Ori ce Dia.
[mm]
Gas
Consumption
[MJ/h]
Auxiliary 0.85 3.60 0.53 3.60
Semi-rapid 1.12 6.30 0.70 6.30
Triple-ring wok 1.65 13.30 0.95 11.90