Fisher & Paykel RF195A Refrigerator User Manual


 
92
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum) 0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) 750 gallons/2838 liters
Maximum Operating Temperature 100° F/38° C
Minimum Pressure Requirement 35 psi/241 kPA
Minimum Operating Temperature 33° F/1° C
Maximum Operating Pressure 120 psi/827 kPA
Performance Data
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig;
pH of 7.5 + 0.5; temp. of 68° + 5° F (20° + 3° C)
** Measurement in Particles/ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
DO NOT use this product where water is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. System certified for
cyst reduction may be used on disinfected water that may
contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR
COMPLIANCE WITH THE STATE AND LOCAL LAWS
AND REGULATIONS.
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Benzene,
Carbofuran, p-Dichlorobenzene,
Mercury & Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards
42 & 53 in models UKF8001AXX-750 for the reduction of:
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #10350-MN-005
100834/B
Standard No. 42: Aesthetic Effects
Parameter
USEPA
MCL
Influent
Challenge Concentration
Influent
Average
Effluent % Reduction
Min. Required
Reduction
Average Maximum Average Minimum
Chlorine 2.0 mg/L ± 10% 1.88 mg/L
<0.05136364
mg/L
0.06 mg/L >97.26% 96.84% 50%
T & O
Particulate** at least 10,000 particles/ml 5,700,000 #/ml 30,583 #/ml 69,000 #/ml 99.52% 98.94% 85%
Standard No. 53: Health Effects
Parameter
USEPA
MCL
Influent
Challenge
Concentration
Influent
Average
Effluent % Reduction
Min. Required
Reduction
Average Maximum Average Minimum
Turbidity 1 NTU** 11 ± 1 NTU*** 10.7 NTU 0.31 NTU .049 NTU 97.09% 95.20% 0.5 NTU
Cysts 99.5% Reduction Minimum 50,000/L 166,500 #/L <1 #/L <1 #/L >99.99% >99.99% > 99.95%
Asbestos 99% Reduction
10
7
10
8
fibers/L; fibers >10
micrometers in length
155 MF/L <1 MF/L <1 MF/L >99.99% >99.99% 99%
Lead at pH 6.5 0.015 mg/L 0.15 mg/L + 10% 0.153 mg/L <.001 mg/L <.001 mg/L >99.35% >99.29% 0.10 mg/L
Lead at pH 8.5 0.015 mg/L 0.15 mg/L + 10% 0.150 mg/L <.001 mg/L <.001 mg/L >99.33% >99.29% 0.10 mg/L
Mercury at pH 6.5 0.002 mg/L .006 mg/L ± 10% 0.006 mg/L 0.0003 mg/L 0.0005 mg/L 95.70% 90.91% 0.002 mg/L
Mercury at pH 8.5 0.002 mg/L .006 mg/L ± 10% 0.006 mg/L 0.0008 mg/L 0.0015 mg/L 86.22% 75.93% 0.002 mg/L
Atrazine 0.003 mg/L 0.009 mg/L + 10% 0.009 mg/L <0.002 mg/L 0.002 mg/L 76.99% 75.31% 0.003 mg/L
Benzene 0.005 mg/L 0.015 mg/L ± 10% 0.014 mg/L 0.0006 mg/L 0.0011 mg/L 95.71% 92.14% 0.005 mg/L
Carbofuran 0.04 mg/L 0.08 mg/L ± 10% 0.081 mg/L <0.001 mg/L <0.001 mg/L 98.74% 98.46% 0.04 mg/L
p-Dichlorobenzene
0.075 mg/L .225 mg/L ± 10% 0.208 mg/L <0.0005 mg/L <0.0005 mg/L 99.76% 99.74% 0.075 mg/L
Lindane 0.0002 mg/L 0.002 mg/L + 10% 0.002 mg/L 0.000 mg/L <0.0001 mg/L 98.72% 96.50% 0.0002 mg/L
Toxaphene 0.003 mg/L 0.015 ± 10% 0.015 mg/L <0.001 mg/L <0.001 mg/L 92.97% 91.67% 0.003 mg/L
The retractable water filtration system uses a UKF8001AXX
replacement cartridge. Timely replacement of filter cartridge
is essential for performance satisfaction from this filtration
system. Please refer to the applicable section of your User
Guide for general operation, maintenance requirements and
troubleshooting. Suggested retail price of replacement water
filter is $39.99.
This system has been tested against ANSI/NSF 42 and 53 for
reduction of the substance listed above. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in ANSI/NSF 42
and 53.
Filter performance data sheet