4-25
9. Press the u (INFO) button. The computer displays 0 DUR. This is the
amount of time the AIF is to remain suspended.
10. Use the number keys to enter a time between 0 and 999
minutes (ex. 1½ hours is entered as 90 minutes). Enter
90 for this example. The computer displays 090
DUR. Four different time periods to suspend filtration
are available for each day or set of days. (M-F 1-4, Sat 1-
4 and Sun 1-4)
11. Press the u (INFO) button to accept time and move to the next time period.
12. When finished, press the button once to exit and return to PRODUCT
selection display.
13. Press the (2) button to quit and to return to OFF.
4.12.2 DEEP CLEAN MODE (BOIL-OUT)
The deep clean mode is used to remove carbonized oil from the frypot.
NOTE: Refer to Kay Chemical “Fryer Deep Clean Procedure” instructions to clean the
LOV™ fryer.
1. Perform steps 1-3 on page 4-23 through 4-24.
The computer displays DEEP CLEAN MODE.
2. Press the (1 yes) button.
Bulk Oil System: Ensure a complete and clean filter pan is in place.
JIB Oil System: Ensure an MSDU or suitable metal container is in place under the drain with a
capacity of FOUR gallons (15 liters) or more.
The computer displays DEEP CLEAN? alternating with yes no.
3. Press the (1 yes) button.
4. Full Vat: Computer displays IS Oil REMOVED? alternating with
Yes No.
Split Vat: Computer displays Deep Clean alternating with L R.
Press the (1) or (2) button under the split vat to be cleaned. The
computer displays IS OIL REMOVED? alternating with yes no*.