Frymaster BIELA14 Fryer User Manual


 
7-3
Problem Probable Causes Corrective Action
M3000 display shows
hot-hi-1.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
Shut the fryer down immediately and
call your ASA for assistance.
M3000 display shows
hELP HI-2 or
High limit
failure.
Failed high limit
Shut the fryer down immediately and
call your ASA for assistance.
M3000 display shows
TEMP PROBE
FAILURE.
Problem with the temperature
measuring circuitry including the probe
or damaged computer wiring harness or
connector.
Shut the fryer down and call your ASA
for assistance.
M3000 display shows
HEATING
FAILURE.
Failed computer, failed interface board,
open high-limit thermostat.
Call your ASA for assistance.
Heating indicator is
on, but fryer is not
heating.
Three phase power cord unplugged or
circuit breaker is tripped.
Verify that both the main power cord and
120V is fully seated in its receptacle,
locked into place and that circuit breaker
is not tripped If the problem continues
call your ASA for assistance.
M3000 display shows
RECOVERY
FAULT and alarm
sounds.
Recovery time exceeded maximum time
limit.
Clear error and silence the alarm by
pressing the 9 button. Maximum
recovery time for electric is 1:40. If this
error continues call your ASA for
assistance.
M3000 display shows
REMOVE
DISCARD.
A product cook is started that has a
different setpoint than the current vat
temperature.
Remove and discard product. Press the
cook button under the display with the
error to remove the error. Reset the
setpoint of the vat before trying to cook
product.
Computer locks up.
Computer error. Call your ASA for assistance.
M3000 displays
SERVICE
REQUIRED followed
by an error message.
An error has occurred which requires a
service technician.
Press 8 (2 NO) to continue cooking and
call your ASA for assistance. In some
cases, cooking may not be available.
7.2.3 Filtration Problems
Problem Probable Causes Corrective Action
Fryer filters after each
cook cycle.
Filter after setting incorrect.
Change or overwrite the filter after
setting by re-entering the filter after
value in level two. See section 4.13.5
on page 4-33.
MAINT FILTER
(Manual Filter) won’t
start.
Temperature too low.
Ensure fryer is at setpoint before
starting MAINT FILTER.
Filter pump won't
start or pump stops
during filtering.
A. Power cord is not plugged in or
circuit breaker is tripped.
A. Verify that the power cord is fully
plugged in and the circuit breaker