Frymaster BIELA14 Fryer User Manual


 
A–1
BIELA14 SERIES GEN II LOV™
ELECTRIC FRYER
APPENDIX A: RTI (BULK OIL) INSTRUCTIONS
A.1.1 Bulk Oil Systems
Bulk oil systems have large oil storage tanks,
typically located in the rear of the restaurant,
that are connected to a rear manifold on the
fryer. Waste oil is pumped from the fryer, via
the fitting located on the bottom, to the
disposal tanks and fresh oil is pumped from
the tanks, thru the fitting located on the top, to
the fryer (see Figure 1). Remove the plate
exposing the RTI connection and connect the
RTI connection to the fryer (see Figure 2). Set
the fryer to bulk through the setup mode and
set all computers to bulk oil. See Section 4.9
on page 4-9. It is imperative that the fryer
system be completely power cycled after
changing setup from JIB to Bulk.
Figure 1
Figure 2
The LOV™ fryers, equipped for use with bulk
oil systems, have an onboard fresh oil jug
supplied by RTI. Remove the cap and insert
the standard fitting into the jug with the metal
cap resting on the lip of the jug. The oil is
pumped in and out of the jug through the same
fitting. (see Figure 3).
Figure 3
The momentary switch used to reset the JIB low LED is also
used to fill the jug in an RTI system. After resetting the JIB
LED, pressing and holding the momentary switch, located
above the JIB, allows the operator to fill the jug from the bulk
oil storage tank (see Figure 4).
To fill the jug, press and hold the JIB reset button until the jug
is full, then release.*
NOTE: Do NOT overfill the jug.
Figure 4
For instructions on filling the vat from bulk, see Section
4.11.4 page 4-22.
* NOTE: It takes approximately twelve seconds from the time the fill JIB button is pressed until the RTI pump
starts. It may take up to 20 seconds before the level in the JIB begins to rise. Typically it takes
approximately three minutes to fill the JIB. It takes approximately one minute to fill a split vat and
two minutes to fill a full vat.
Fresh Oil
Connection
Waste Oil
Connection
WARNING:
Do not add HOT or
USED oil to a JIB.
NOTE: The instructions in this manual for using a bulk oil system for filling and discarding oil are for
an RTI system. These instructions may not be applicable to other bulk oil systems.
RTI wiring
connection
(behind
plate).