5-5
The computer displays REMOVE PAN.
*NOTE: If the filter pad change time has expired, normally every 25 hours,
the CHANGE FILTER PAD? message repeats every 15 minutes
instead of every four minutes.
6. Remove the pan. The computer display changes to CHANGE PAD. Change the filter pad and
ensure the filter pan has been pulled forward, out of the cabinet for at least 30 seconds. Once the
pan has been out for 30 seconds the computer displays OFF. Ensure the pan is dry and
assembled correctly. Push the filter pan back into the fryer. Ensure “A” is displayed on the MIB
board.
7. Switch the computer on. The computer displays low temp until the fryer reaches setpoint.
8. If a filtration error occurs six consecutive times, the return valve closes and the computer
displays SERVICE REQUIRED alternating with YES and an alarm.
9. Press 9 (1 yes) to silence alarm and continue.
The computer displays SYSTEM ERROR and the error message for 15
seconds changing to SYSTEM ERROR FIXED alternating with YES
NO.
10. Press 8 (2 NO) to continue cooking. Call your ASA to repair and reset
the fryer. The error will be re-displayed every 15 minutes until the issue
is repaired. Auto filtration and auto top off is disabled until the fryer is
reset.