Frymaster BIELA14 Fryer User Manual


 
4-36
SPLIT VAT CONFIGURATION
a. DAY (wed), DATE (03/20/07) – Current day and date.
b. l fIltErEd # DAy – Number of times left vat filtered and day.
c. L flt bpsd # day, – Number of times left vat filter was bypassed and day.
d. L flt avg day, – Average number of cook cycles per filter/left vat and day.
e. R filtered # day, – Number of times right vat filtered and day.
f. R flt bpsd # day, – Number of times right vat filter was bypassed and day.
g. R flt avg day, – Average number of cook cycles per filter/right vat and day.
5. Press the (2) button to return to INFO MODE changing to filter
stats prompt.
6. Press the (2) button again to quit.
The computer displays OFF.
4.14.2 REVIEW USAGE MODE
The review usage displays total cook cycles per vat, number of cook cycles per vat, number of cook
cycles exited prior to completion, the number of hours the vat(s) have been on and the date of last
usage reset.
1. Perform steps 1-3 on pages 4-34 through 4-35.
Scroll to review usage.
2. With review usage displayed, press the (1 yes) button.
The computer displays USAGE SINCE changing to the date and time that the usage was last
reset.
3. Press the t and ubuttons to scroll between:
FULL VAT CONFIGURATION
a. usage since time, date – Usage since date and time of last reset.
b. total cooks # – Number of cook cycles for all products.
c. quit cook # – Number of cook cycles exited within first 30 seconds.
d. on hrs # – Number of hours the vat has been on.
e. reset usage – Resets usage counters.
SPLIT VAT CONFIGURATION
a. usage since time, date – Usage since time and date of last reset.
b. total cooks # – Number of cook cycles for all products.
c. quit cook # – Number of cook cycles exited within first 30 seconds.
d. L on hrs # – Number of hours the left vat has been on
e. R on hrs # – Number of hours the right vat has been on
f. reset usage – Resets usage counters.