5-1
BIGLA30 SERIES GEN II LOV™ GAS FRYER
CHAPTER 5: FILTRATION INSTRUCTIONS
5.1 Introduction
The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered
while the other frypots in a battery remain in operation.
Section 5.2 covers preparation of the filter system for use. Operation of the system is covered in
Section 5.3.
WARNING
The on-site supervisor is responsible for ensuring that operators are made aware of
the inherent hazards of operating a hot oil filtering system, particularly the aspects
of oil filtration, draining and cleaning procedures.
WARNING
The filter pad or paper MUST be replaced daily.
5.2 Preparing the Filter for Use
1. Pull the filter pan out from the cabinet
and remove the crumb tray, hold-down
ring, filter pad (or paper), and filter
screen. (See Figure 1) Clean all metal
parts with a solution of All Purpose
Concentrate and hot water then dry
thoroughly.
The pan cover must not be removed
except for cleaning, interior access, or to
allow a shortening disposal unit
(MSDU) to be positioned under the
drain. If using an MSDU built before
January 2004 see instructions on page 4-
16.
2. Inspect the filter pan connection fitting
to ensure that both O-rings are in good
condition. (See Figure 2)
Figure 1
Figure 2
Inspect the filter
connection fitting
O-rings.