Frymaster BIGLA30 Fryer User Manual


 
7-3
7.2.2 Error Messages and Display Problems
Problem Probable Causes Corrective Action
M3000 display shows
hot-hi-1.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF (202ºC).
Shut the fryer down immediately and
call your ASA for assistance.
M3000 display shows
REMOVE
DISCARD.
A product cook is started that has a different
setpoint than the current vat temperature.
Remove and discard product. Press the
cook button under the display with the
error to remove the error. Reset the
setpoint of the vat before trying to cook
product.
M3000 display shows
RECOVERY
FAULT and alarm
sounds.
Recovery time exceeded maximum time
limit.
Clear error and silence the alarm by
pressing the 9 button. Maximum
recovery time for gas is 2:25. If the error
continues call your ASA for assistance.
M3000 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
Toggle between F° to C° by pressing
and holding 3and4simultaneously
until TECH MODE appears. Enter
1658. The computer displays OFF.
Turn the computer on to check
temperature. If the desired scale is not
displayed, repeat.
M3000 display shows
hELP HI-2 or
High limit
failure.
Failed high limit
Shut the fryer down immediately and
call your ASA for assistance.
M3000 display shows
TEMP PROBE
FAILURE.
Problem with the temperature measuring
circuitry including the probe or damaged
computer wiring harness or connector.
Shut the fryer down and call your ASA
for assistance.
M3000 display shows
HEATING
FAILURE.
Gas valve off, failed computer, failed
transformer, open high-limit thermostat.
It is normal for this message to appear
during startup if the lines have air in
them. Check that the gas valve is on. If
it continues, shut the fryer down and
call your ASA for assistance.
M3000 displays
SERVICE
REQUIRED
followed by an error
message.
An error has occurred which requires a
service technician.
Press 8 (2 NO) to continue cooking and
call your ASA for assistance. In some
cases, cooking may not be allowed.
7.2.3 Filtration Problems
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Fryer filters after each
cook cycle.
Filter after setting incorrect.
Change or overwrite the filter after setting
by re-entering the filter after value in level
two. See section 4.13.5 on page 4-33.
MAINT FILTER
(Manual Filter) won’t
start.
Temperature too low.
Ensure fryer is at setpoint before starting
MAINT FILTER.
M3000 display shows
filter busy.
A. Another filtration cycle or filter pad
change is still in process.
B. MIB has not cleared checking system.
A. Wait until the previous filtration
cycle ends to start another filtration
cycle. Change filter pad if prompted.
B. Wait one minute and try again.