Fujitsu MAN3735 Water Dispenser User Manual


 
C141-E124-01EN4 - 4
"0" : Data blocks which contain errors that are impossible to correct are not transferred to the
INIT during a read operation.
d. RC (read continuous)
This bit specifies continuous transfer of all the data requested by a command unaccompanied
by a delay for executing error recovery processing.
The IDD disregards the specification in this bit and operates according to the default value
(=0).
e. EER (enable early recovery)
"1" : When a correctable data check has been detected, data correction according to the ECC
is applied immediately without executing retry (rereading) up to the number of times
specified in the "Number of retries during READ" parameter.
"0" : When a correctable data check has been detected, retry (rereading) is executed up to the
number of times specified in the "Number of retries during READ" parameter, then data
correction according to the ECC is applied if possible.
The IDD disregards this bit and operates according to the default value (=1).
f. PER (post error)
"1" : When several errors (errors related to the disk drive), which were recovered from
normally through the IDD's error recovery processing, have been detected, a CHECK
CONDITION status is reported when execution of that command is completed. In the
sense data generated at this time, the sense key indicates "RECOVERED ERROR [=1]"
and the content of the first error to be corrected successfully is reported.
"0" : Even when several errors (errors related to the disk drive), which were recovered from
normally through the IDD's error recovery processing, have been detected, that
command is completed with a GOOD status and the contents of the recovered errors are
not reported.
g. DTE (disable transfer on error)
"1" : Even when several errors on the disk drive, which were recovered from normally
through the IDD's error recovery processing, have been detected, execution of that
command terminates at that point.
"0" : When several errors on the disk drive, which were recovered from normally through the
IDD's error recovery processing, have been detected, execution of that command is
continued.
The IDD disregards this bit and operates according to the default value (=0).