Fujitsu MAN3735 Water Dispenser User Manual


 
C141-E124-01EN 5 - 19
Table 5.3 Sense data error classification (4 of 4)
K
*
C
*
Q
*
Error contents L
*
Recovery method
(See Table 4.4.)
E 1D 00 Miscompare during verify operation None 24
Data failed to match in the Byte check mode of the
Verify command.
* K: Sense Key C: Sense Code
Q: Sub-sense code L: Logging Necessary? (shown in Section 5.2.3)
Table 5.4 Error recovery processing procedures (1 of 5)
Recovery
Method
Recovery Processing Procedure
0 It is not necessary to perform the error recovery processing. Continue processing.
1 Error recovery processing is impossible. Terminate processing.
2 This is a programming error and error recovery processing is impossible. Terminate
processing and correct the error in the system (INIT) programming.
3 This is an error in the SCSI protocol and error recovery processing is impossible. Terminate
processing and check the system's SCSI bus operation.
4 1) Reissue the original command. (Retry)
2) If the command is terminated with the same error when retried, perform recovery
method 3 or 1.
3) If the command is terminated with a different error when retried, execute the recovery
processing procedure for that error.
5 1) After waiting about 1 second, reissue the original command (Retry).
2) If it doesn't recover after 10 retries, perform recovery method 1.
6 1) Reissue the original command. (Retry)
2) If it doesn't recover after 10 retries, perform recovery method 3.
7 1) Reissue the original command. (Retry)
2) If it doesn't recover after 10 retries, perform recovery method 1.