Fujitsu MAN3735 Water Dispenser User Manual


 
C141-E124-01EN4 - 26
"F" :Data put into the cache via a READ command was not replaced if there is other data in
the cache that was placed into the cache by other means and it may be replaced.
"1" : Data put into the cache via a READ command was replaced sooner than data placed into
the cache by other means.
"0" : Indicates the device server was not distinguish between retaining the indicated data and
data placed into the cache memory by other means.
h. Write Retention Priority (not supported)
This field advises the device server the retention priority to assign for data written into the
cache that has also been transferred from the cache memory to the medium.
"F" : Data put into the cache during a WRITE or WRITE and VERIFY command was not
replaced if there is ohter data in the cache that was placed into the cache by other means
and it may be replaced.
"1" : Data put into the cache during a WRITE or WRITE and VERIFY command was
replaced sooner than data placed into the cache by other means.
"0" : Indicates the device server was not distinguish between retaining the indicated data and
data placed into the cache memory by other means.
i. Pre-fetch inhibit block count (not supported)
This parameter is used to selectively prohibit data Look-Ahead operations in the READ
command or the READ EXTENDED command. When the "Transfer block count" specified in
the CDB of the READ command or the READ EXTENDED command is greater than the
value in this parameter, data Look-Ahead operations are not executed in that command. This
bit cannot be changed. The IDD disregards the specification in this bit and operates according
to the "Default" value (= X 'FFFF').
j. Minimum pre-fetch (not supported)
This parameter specifies the minimum quantity of logical data blocks pre-fetched to the data
buffer with the READ command or READ EXTENDED command.
This parameter cannot be changed. The IDD disregards the specification in this field.
k. Maximum pre-fetch (not supported)
This parameter specifies the maximum quantity of logical data blocks pre-fetched to the data
buffer with the READ command or READ EXTENDED command.
The IDD varies the pre-fetch volume according to the volume of data requested by the READ
command or READ EXTENDED command. The value reported to the MODE SENSE
command always indicates the number of blocks corresponding to 1 cache segment – 1.
This parameter cannot be changed. The IDD disregards the specification in this field.