6. Disconnect the turbine probe from the turbine
assembly.
7. Lift the control off the valve, Figure 15. To replace the
control, reverse the above procedure. Note that the
camshaft needs to be positioned correctly before it
can be inserted into the back of the control. There is a
locating arrow on the camshaft. Position the arrow on
the top of the shaft and slide the camshaft into the
control. Push up on the end of the camshaft, furthest
from the timer, snapping it into place.
Figure 15