GE FGB-M05 Blender User Manual


 
Rev. May 2001 GraviMaster-FGB-M05 (S) Page 12
Gravimetric Blender
2.7.5.2 Stock Silo Control
A regrind silo can have (optional) three sensors to detect high- low- and middle. If the
controller has these sensors, Stock-Silo regrind control can be activated, choosing menu
(F1) controller / protected parameters.
If the high-sensor is true, the silo is almost full. Therefore more regrind will be dispensed.
This is the same as described in empty regrind control. This will be done until the middle
sensor is not true anymore. In a de ned number of steps the process will dispense the
original setting of the recipe.
If the low-sensor is true, the silo is almost empty. Therefore less regrind will be dispensed.
This is the inverse as described in empty regrind control. This will be done until the
middle sensor will become true. In a de ned number of steps the process will dispense
the original setting of the recipe.