GE FGB-M05 Blender User Manual


 
Rev. May 2001 GraviMaster-FGB-M05 (S) Page 28
Gravimetric Blender
Step: Use the arrow-keys <↓> to select a component and press <ENTER>.
Use the arrow-key <?> to select Quantity. Enter the quantity and press <ENTER>.
Use the arrow-key <→> to select Alarmtype and press <ENTER>.
Alarm
Ignore
Ignore
Warning
Error
Step: Select an alarm type by using the arrow-keys and press <ENTER>.
It is not necessary to enter a speed (g/s) because the terminal already has entered
standard values and the GraviMaster calculates new speeds and updates the recipe.
Step: Press the arrow-key <ο> to select the next hopper number.
Depending on the model, it is possible to use upto 12 hoppers.
The terminal has a keyboard but the keyboard doesnt contain characters. Therefore it is
possible to connect a standard AT keyboard to the terminal. This keyboard must connect to
a connector which is placed on the PCB in the terminal. When using a AT keyboard, than:
Switch power off the terminal
Disconnect the internal keypath from the PC board
Connect the AT keyboard on the PC board
Switch on the terminal
Now you can use the AT-keyboard. When you are ready, than connect the terminal-keyboard
again. This has to be done when the terminal is switched off.
3.2.3 Change current recipe
When an operator wishes to produce a new product a change of the current recipe must be
done. To change the current recipe select menu (F1) controller / select recipe. The terminal
now shows a list with all recipes. The recipe which is marked with an <↓> is the actual
recipe, this recipe is also loaded in the controller.
IMPORTANT
When a new recipe is selected be sure that all hoppers are lled with material. The controller
calculates new dispense-rates by a fast algorithm in the rst 5 batches.