GE FGB-M05 Blender User Manual


 
Rev. May 2001 GraviMaster-FGB-M05 (S) Page 33
Gravimetric Blender
PUBLIC PARAMETERS
Parameter Description Init
AlarmReport Indicates if alarm-reports must be printed. No
*)
ProductionReport Indicates if production-reports must be printed. No
*)
If so the parameter interval-time must be given also.
Interval
Pauze (time) before printing the next production-report.
01:00.00
BatchReport Indicates if batch-reports must be printed. No
*)
ProductionMode Actual production-mode. There are three possible CONTINUE
modes; CONTINUE, WEIGHT and ALARM_
WEIGHT. If the mode WEIGHT os ALARM_
WEIGHT has been selected the parameter production
Weight must also be given.
ProductionWeight The FGB stops his production when the production 100 [Kg]
Weight is reached. (productionMode must be
WEIGHT or ALARM_WEIGHT).
DispenseMode Actual dispense-mode. There are three possible GRAVIMETRIC
modes; GRAVIMETRIC, VOLUMETRIC and
COMBINATION. If the mode COMBINATION is
chosen the parameter combinationRatio must be given.
CombinationRatio Relation between the volumetric and gravimetric 3
dispenses. (one gravimetric dispense and x
volumetric dispenses).
MixMode Actual mixermode. There are four possible modes; PULSE
ON, OFF, NORMAL and PULSE. In normal-mode
the parameter mixerOnTime must be given. In the
mode pulse the parameters mixerPulseOnTime and
mixerPulseOffTime must be given.
MixerOnTime Time the mixer is activated after the material is 10 [s]
dumped out of the weighbin.
MixerPulseOnTime Time the mixer is activated in pulse-mode. 5 [s]
MixerPulseOffTime Time the mixer is not activated in pulse-mode. 15 [s]
AdditiveToRegrind Percentage additive to regrind which must be added. 0 [%]
Percentage 1/2
AdditiveToRegrind Hoppernumber in which the additive is. Hopper 5
Hopper 1/2
WeighbinDumpTime Time the weighbinvalve is activated (dumping of 4 [s] 0,5 kg unit
material into the mixerchamber). 6 [s] 1,2,5 and
25 kg unit
LevelControlWaitTime Time between the full signal of the mixerchamber 8 [s]
sensor and opening the mixerchamber-valve.
LevelControlDumpTime Time between the free signal of the mixerchamber
sensor and closing the mixerchamber-valve. 1 [s]
*) No = [ ], Yes = [X]