JXBC57 Kit
For Outdoor Remote Blower Locations
3
(continued)
Step
• Remove the 4 nuts holding the blower to the
mounting plate. One nut is hidden inside
the outlet. Remove blower.
• Remove the blower mounting plate.
• Remove 2 screws along the bottom of the
blower box which are visible once blower
plate is removed.
• Carefully, turn the unit over to access the
back side.
• Remove 4 screws along the top of the blower
box.
• Turn the unit over and remove the 4 screws
along the top.
• Remove the blower box.
• Retain all screws.
Important: Save any unused parts. If the
appliance is relocated at a later time, parts
may be needed.
• The downdraft plenum can discharge from
either the right or left side. Select the side
that provides the best alignment to ductwork
extending to the blower assembly.
– For a left side discharge, install the outlet
plate to the bottom of the plenum on the
left side. Install the cover plate to the
bottom of the right side. Reverse plates for
a right side discharge.
.
• A transition is required to connect the
3-1/4" x 10" duct to the 6" round inlet on
the blower.
• Tape to seal all joints.
4
Connect
Blower
Wires
Step
• Check that the red plastic anti-short bushing
is secured in the end of the conduit. Install
the blower conduit into the conduit connector
on the junction box and tighten the screw.
• Install a liquid tight fitting in the hole of the
wire compartment on the base, sized to fit wire
being used.
• Run the electrical wiring from the downdraft
vent to the wire compartment.
• Attach the green ground leads from the wire
compartment, connecting one to the green
ground lead on the blower and the other to
the ground lead of the wiring from the
downdraft vent.
• Connect the neutral (white) and power lead
(black) from the blower to the leads from the
downdraft vent.
• Use wire nuts to connect wires.
Blower
Conduit
Red Anti-
Short Bushing
Conduit
Connector
Wire
Compartment
Green Ground
Leads
Base
Assembly
Wires
to Vent
Strain
Relief
Blower
Blower
Mounting
Plate
Blower Box
Hidden
Screws
Duct Adapter
Outlet Cover
Downdraft