GE Monogram ZGU365 Cooktop User Manual


 
20
JXBC57 Kit
For Outdoor Remote Blower Locations
5
Connect
Electrical
Step
• Use electrical cable and connectors that
conform to local codes (14 gauge min. is
recommended). Use a length to reach
between the vent and the blower/motor
location.
• Attach the wire box removed from the
blower conduit to the end of new wiaring.
• Use wire nuts to secure the wire to the 3"
remaining wires with plug.
• Insert the plug into the mating plug on the
vent.
• Reinstall wire box with original screws.
• Mount the blower onto the mounting plate.
Secure with original nuts.
• Install damper to bottom of outlet with 4
screws.
6
Mount
Blower
Step
Wiring to Blower Junction Box
Provided
Mounting
Screws
Blower
Wire
Box
Wire Nuts
3-Wire
Connectors
Plenum
• Place the cover over the the assembled kit
and secure with 16 screws.
7
Finalize
Installation
Step