The supply power cords shall be oil-resistant, sheathed flexible
cable, no lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord.
It is recommended that a 30 mA rated protective device such as
a residual current circuit breaker (RCCB), or ground fault
circuit interrupter (GFCI), be used on the fryer circuit.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces in
close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol .