Hobart 6801 Mixer User Manual


 
11
CLEANING AND SANITIZING
WARNING: DISCONNECT ELECTRICAL POWER AND PLACE A TAG AT THE DISCONNECT
SWITCH INDICATING THE CIRCUIT IS BEING WORKED ON BEFORE CLEANING THIS MACHINE.
The saw must be thoroughly cleaned and sanitized:
Before first use;
After each day's operation;
Anytime it is not to be used for an extended period of time; or
Before being put into operation after an extended downtime.
The meat saw can be cleaned with high-pressure cleaning equipment (available from other suppliers)
or it can be disassembled and its components cleaned in a sink. In either case, a neutral pH cleaning
agent mixed per the supplier's instructions should be used. After washing, thoroughly sanitize, rinse,
and dry the saw and all components.
Disassemble the following saw components to allow access to all areas for cleaning . . .
Upper Pulley Cover
Lower Cover (Scrap Pan)
Tables Right and Left-Hand
Scrap Tray
Carriage
Column Guard
Pulley Wiper
Blade Scrapers
Lower Blade Guide Assembly
Saw Blade
Upper Guide and Guard Assembly (unscrew Hand Knob to disassemble)
Upper and Lower Pulleys
If using High-Pressure Cleaning Equipment . . .
Scrape the machine and its components to remove any scrap particles before cleaning.
Thoroughly hose the saw and its components following the equipment supplier's instructions. Be
sure to get the hose stream into all corners. Stubborn soil may require a little brushing.
If using Sink Cleaning . . .
Use a cloth or brush on base unit. Thoroughly wash, sanitize, rinse, and dry.
Before reassembly, a light coating of tasteless mineral oil should be applied to all metal surfaces.
Lubricate six ball bearings on the carriage with a small amount of mineral oil. Apply a few drops of
mineral oil to the gauge plate slide rod and work the gauge plate assembly back and forth a few times.
Reassemble the saw components in reverse order of disassembly making sure all parts are properly
assembled.
6801 Meat Saw Technical Manual Page 17 of 51