Hobart 6801 Mixer User Manual


 
HEATER
COIL
C1 C3
L2
L1 L3
C
NCNO
T1 T3T2
DD1 DD2
H4 H3 H2 H1
TRANSFORMER
(T)
MTR
23
S1
START
SWITCH
SYMBOL DEFINITIONS
CON-
CONTACTOR
MTR-
MOTOR
SWITCH - MOMENTARY
SWITCH - MAINTAINED
CONTACT NORMALLY OPEN
CONTACT NORMALLY CLOSED
FIXED PREWIRING PRINTED
CIRCUIT OR OTHER
DEVICE OUTLINE
EXTERNAL WIRING
CONTROL PANEL HEATER
L1
L2
L1
T1
L2
T2
L3
T3
1CON
MACHINE
GROUND
C1
1CON
4C3
S1
32
MTR
1CON
SERVICE CONNECTIONS
CNO
T1
T2
T3
1
L3
BOX HEATER
WARNING
ELECTRICAL AND GROUNDING
CONNECTIONS MUST COMPLY WITH
THE APPLICABLE PORTIONS OF THE
NATIONAL ELECTRICAL CODE AND/OR
OTHER LOCAL ELECTRICAL CODES
C1
1CON
4C3
S1
32
1CON
C
NO
1
BOX HEATER
SERVICE CONNECTIONS
L1
L2
L1
T1
L2
T2
L3
T3
1CON
MACHINE
GROUND
L1
H2
H4
L2
MTR
T1
T2
T3
L3
.8
AMP
FUSE
BOARD
FB
H1
F2
F1
DD2
DD1
H3
.8
AMP
T
XFMR
BL
BL
W
BK/R
BK/W
BK
NC
T2 TO
T1 TO
MOTOR CONNECTIONS
220/50/3
200-230/60/3
VOLTAGE T3 TO
INTERCONNECT
T1,T7
T2,T8 T3,T9
T3,T11
T2,T10
T1,T12
T4-T5-T6
T4-T7,T5-T8,T6-T9
WIRING DIAGRAM
MEAT SAW
MODELS 6614/6801
DERIVED FROM F-34512 REV A
200-230/60/3
T4-T7,T5-T8,T6-T9
T1
T2 T3
460/60/3
380-415/50/60/3
CONTACT0R(1CON)
460/60/3
AI 2717
6801 Meat Saw Technical Manual Page 20 of 51