–15–
Program Lock
This feature allows you to lock the memory pads’ power levels and heating times and allows one touch
operation of the oven (pressing START is not required).
1. Remove the right air filter.
2. Press and hold in the PROG LOCK button for 5 seconds until the display
shows PROG P L .
Do not press PROG LOCK for more than 30 seconds or a false failure
<code F44> may occur.
3. After 3 seconds, the display goes blank.
4. Reinstall the air filter.
When PROG LOCK is active, opening the door cancels the time remaining. The memory pads cannot
be reprogrammed until PROG LOCK is deactivated. See Program Features chart.
Program Unlock
This procedure deactivates PROG LOCK, allows memory pads to be programmed and requires you
to press START after selecting a memory pad.
1. Remove the right air filter.
2. Press and hold in the PROG LOCK button for 5 seconds until the display
shows PROG P.
Do not press PROG LOCK for more than 30 seconds or a false failure
<code F44> may occur.
3. After 3 seconds the display goes blank.
4. Reinstall the right air filter.
When PROG UNLOCK is active, opening the door does not cancel the time remaining. To continue,
close the door and press Start. The memory pads can be reprogrammed. See Program Features chart.
Beep Tone and Duration can be programmed.
serutaeFmargorP
taepeRotuAtpurretnI
'dekcolnU'PGORP
noitarepOlaunaM
daPyromeM
*seY
oN
*seY
*seY
'dekcoL'LPGORP
noitarepOlaunaM
daPyromeM
*seY
oN
*seY
oN
* Press <START> to repeat or resume.