– 18 –
DEFROST
NOTE: DEFROST starts automatically after 6 hours of
chilling but only if operating in Holding mode.
From the Main Menu, select MORE and DEFROST.
• To begin Defrosting, remove food and select START.
(CANCEL returns to the Main Menu.)
• The DEFROST cycle runs 20 minutes or until the Coil
Temperature reaches 50°F.
(EXIT returns to the Main Menu.)
• If DEFROST NOT REQUIRED is displayed, return to
Main Menu is automatic.
PRINT —
Once a chill cycle is done, data can be printed.
From the Main Menu, select MORE and PRINT.
• The last chill cycle displays Probe # (if BY TEMP),
MM/DD (= month/day), and HH:mm (= hour:minute).
Probe # will not display if the chill cycle was BY TIME.
• Select the Cycle you want to print by pressing ← (for
previous) and → (for next).
• Press PRINT.
(MAIN returns to the Main Menu.)
• To print, select RECORD, LABEL or BOTH. After
printing, the display returns to the Main Menu.
(NONE returns to the Main Menu.)
PRINT CYCLE #____
PROBE #_ MM/DD HH:mm→
←BACK SELECT NEXT→
MAIN MENU PRINT
PRINT PROBE #_
RECORD
LABEL
NONE BOTH
DEFROSTING
COIL 12
°F
TIME REMAINING 19:52
EXIT
READY TO DEFROST
REMOVE FOOD
CANCEL START
DEFROST
NOT REQUIRED
MAIN MENU 08:05:01
BY TEMP BY PROD
BY TIME
MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
MAIN MENU 08:05:01
BY TEMP BY PROD
BY TIME
MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK