ELECTRICAL CONNECTIONS
Line voltage supplied to the cabinet junction box must not be affected by the operation of other
electrical equipment. Junction box is located at the rear of the lower section. The rear compressor
cover is maintained in place with Velcro. Pull to remove it.
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
The circuit should be protected with a Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker.
INSTALLATION OF REMOTE ALARM (Optional)
The chiller provides a connection for a remote alarm that operates when the buzzer sounds on
completion of a chill cycle. Connect to terminals on terminal block (# 5 and # 6 in the upper section
of the chiller) per the wiring diagram and these restrictions:
1. Maximum remote alarm rating: 120
240 Volts at 2 amps resistive or 100 watt incandescent lamp.
2. Connection must be made of 600 volt insulated wire suitable for supply voltage. Do not use bell
wire, lamp cord or similar type wire.
INSTALLATION CHECKOUT
The self-contained refrigeration system (when equipped) is shipped fully charged with refrigerant and
requires only proper electrical connections. Remote refrigeration systems must be installed, connected
and charged by others.
After proper electrical connections are made, place the switch next to the control in the On position.