– 28 –
• Access the Sys Par 2 menu as shown on page 21.
• From Sys Par 2, select MODE.
MODE
• From Mode Parameters, select FREEZE.
(BACK returns to SYS PAR 2.)
FREEZE
• Set the TARGET Temp using the ↓ or ↑ keys.
Range: [–22°F to 28°F].
• Select NEXT to move to the next field.
• Set the AIR Temp using the ↓ or ↑ keys.
Range: [–32°F to 20°F].
• Select NEXT to move to the next field.
(BACK returns to the previous field.)
• Set the HOLD Temp using the ↓ or ↑ keys.
Range: [–32°F to 20°F].
• Select NEXT to move to the next field.
• Set the HIGH ALARM Temp using the ↓ or ↑ keys.
Range: [1°F to 35°F].
• Select NEXT to move to the next field.
• Set the LOW ALARM Temp using the ↓ or ↑ keys.
Range: [–30°F to 0°F].
(NEXT returns to the TARGET TEMP field.)
• Select ENTER to accept the displayed values and
return to Mode Parameters.
(CANCEL retains the previous settings and returns to
Mode Parameters.)
NOTE: Freeze Mode is only available on
model HQCF45.
MODE PARAMETERS
CHILL FREEZE
SOFT CHILL
BACK
FREEZE MODE EDITOR
↓TARGET 0
°F↑
←BACK NEXT→
CANCEL ENTER
FREEZE MODE EDITOR
↓AIR -25
°F↑
←BACK NEXT→
CANCEL ENTER
FREEZE MODE EDITOR
↓HOLD -6
°F↑
←BACK NEXT→
CANCEL ENTER
FREEZE MODE EDITOR
↓HIGH ALARM 32
°F↑
←BACK NEXT→
CANCEL ENTER
FREEZE MODE EDITOR
↓LOW ALARM -20
°F↑
←BACK NEXT→
CANCEL ENTER