Hobart ML-124070 Refrigerator User Manual


 
36
Access the Sys Par 2 menu as shown on page 30.
From Sys Par 2, select MODE.
MODE
From Mode Parameters, select SOFT CHILL.
(BACK returns to SYS PAR 2.)
SOFT CHILL
Assures against freezing by reducing air flow at end of cycle or by increasing air temp.
[ % ] x Chill Time = Time when reduced air flow occurs.
Range: [10% to 90% ].
Set the By Time % using the or keys.
Select NEXT to move to the next field.
[_°F ] + Target Temp = Temp when reduced air flow occurs.
Range: [ 5 to 20 °F].
Set the By Temp degrees using the or keys.
Select NEXT to move to the next field.
(BACK returns to the previous field.)
[ 2nd Temp ] = Sets an alternate Air Temp during the Soft Chill cycle.
Range: [ 10°F to 40°F ]. Normal Air Temp (regular chill cycle) = 10°F.
Set the 2nd Temp degrees using the or keys.
(NEXT returns to the By Time field.)
Select ENTER to keep any changes and return to
Mode Parameters.
(CANCEL retains the previous settings and returns to
Mode Parameters.)
MODE PARAMETERS
CHILL FREEZE
SOFT CHILL
BACK
SOFT CHILL EDITOR
BY TIME 70%
BACK NEXT
CANCEL ENTER
SOFT CHILL EDITOR
BY TEMP 5
°F
BACK NEXT
CANCEL ENTER
SOFT CHILL EDITOR
2ND TEMP 28
°F
BACK NEXT
CANCEL ENTER
SYS PAR 1 09:07:31
CLOCK TEMPS IN °F
PROBES LOGGING
SETUP MENU MORE
SYS PAR 2 09:08:41
REMOTE ALARM MODE
ALARMS BUZZER
BACK FAC PRESETS