Hoshizaki DCM-300BAH(-OS) Ice Maker User Manual


 
11
C. Location
CAUTION
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.
2. This icemaker will not work at sub-freezing temperatures. To prevent
damage to the water supply line, drain the icemaker if the air temperature is
goingtogobelow32°F(0°C).See"III.C.PreparingtheIcemakerforLong
Storage."
IMPORTANT
Opti-Serve Models (-OS): Sunlight, direct and indirect, can have an effect on
the operation of the dispense sensors. If a problem is noticed, the icemaker
should be moved out of direct sunlight and/or farther away from any outside
windows.
For best operating results:
•Theicemakershouldnotbelocatednexttoovens,grills,orotherhighheatproducing
equipment.
•Thelocationshouldprovidearmandlevelfoundationfortheequipment.
•Allow6"(15cm)clearanceatrearandsidesforproperaircirculationandeaseof
maintenanceand/orserviceshouldtheyberequired.Allow24"(61cm)clearanceattop
to allow for removal of the auger.
D. Setup
1) Position the icemaker in the selected permanent location. If applicable, attach optional
6"legsorattachtoanoptionalstand.Ifattachingtoastand,refertotheinstructions
included with the stand.
2) Level the icemaker in both the left-to-right and front-to-rear directions. If using optional
6"legsoranoptionalstand,adjustthelegstomaketheicemakerlevel.
3) If mounting at to a counter, seal the perimeter where the icemaker contacts the
counter with approved caulk compound in a smooth and easily cleanable manner.
4) Replace the panels in their correct positions.