Hoshizaki DCM-300BAH(-OS) Ice Maker User Manual


 
13
F. Water Supply and Drain Connections
See Fig. 4.
WARNING
1. Water supply and drain connections must be installed in accordance with
applicable national, state, and local codes and regulations.
2. Normal operating water temperature should be within 45°F to 90°F (7°C
to 32°C). Operation of the icemaker, for extended periods, outside of this
normal temperature range may affect icemaker performance.
3. To prevent damage to equipment, do not operate the icemaker when the
water supply is off, or if the pressure is below 10 PSIG. Do not run the
icemaker until the proper water pressure is reached.
•Aplumbingpermitandservicesofalicensedplumbermayberequiredinsomeareas.
•Externallters,strainers,orsoftenersmayberequireddependingonwaterquality.Contact
your local Hoshizaki distributor for recommendations.
•Watersupplypressureshouldbeaminimumof10PSIGandamaximumof113PSIG.If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
•Thestoragebindrainlineanddriptraydrainlinemustberunseparately.
•Drainlinesmusthave1/4"fallperfoot(2cmper1m)onhorizontalrunstogetagood
ow. A vented tee connection is also required for proper ow.
•Drainlinesshouldnotbepipeddirectlytothesewersystem.Anairgapofaminimumof
2 vertical inches (5 cm) should be between the end of the drain pipes from the storage bin
and drip tray and the oor drain.