Spout B
Spout A
9)Movethecontrolswitchtothe"ICE"position.Opentheicemakerwatersupplyline
shut-off valve to supply water to the reservoir.
10)Afterthegearmotorstarts,movethecontrolswitchtothe"DRAIN"position.Allowthe
water system to drain for 5minutes.
11)Movethecontrolswitchtothe"ICE"position.Allowtheicemakertorunfor30minutes,
then clean and sanitize the dispensing components as outlined below.
2. Dispensing Components
Perform after cleaning and sanitizing the water system as outlined above.
a) Cleaning Solution
Dilute9.6.oz.(0.29l)ofHoshizaki"ScaleAway"with1.6gal.(6.0l)ofwarmwater.
b) Sanitizing Solution
Dilute 0.82 . oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with
1.6 gal. (6.0 l) of warm water.
c) Cleaning and Sanitizing Procedure
1)Movethecontrolswitchtothe"OFF"position,thenturnoffthepowersupply.
2)Removethefrontandtoppanels,thenmovethepowerswitchtothe"OFF"position.
3) Remove the storage bin cover.
4) Remove the motor bracket thumbscrews, rst from the vertical plane and then from
the horizontal plane. While holding on to the corresponding agitator or auger, move
the agitating motor or the dispensing motor towards you. Remove the agitator and the
dispensing auger from the storage bin. See Fig. 7.
5) Remove the bin control assembly. See Fig. 8.
6) Remove the snap pin, shaft, and actuator.
7) Remove spout B, spout A, and their gaskets.
Fig. 8
Bin Control
Bracket
Snap Pin
Shaft
Actuator