Hoshizaki DCM-300BAH(-OS) Ice Maker User Manual


 
19
A. Cleaning and Sanitizing Instructions
Hoshizaki recommends cleaning and sanitizing this unit at least twice a year. More
frequent cleaning and sanitizing, however, may be required in some existing water
conditions.
WARNING
1. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
2. Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
3. Always wear liquid-proof gloves and goggles to prevent the cleaning and
sanitizing solutions from coming into contact with skin or eyes.
4. Do not use ice made from the cleaning and sanitizing solutions. After cleaning
and sanitizing, be careful not to leave any solution on the parts or in the
storage bin.
1. Water System
a) Cleaning Solution
Dilute9.6.oz.(0.29l)ofHoshizaki"ScaleAway"with1.6gal.(6.0l)ofwarmwater.
b) Cleaning Procedure
1) Close the icemaker water supply line shut-off valve.
2)Movethecontrolswitchtothe"DRAIN"position.SeeFig.7.Allowthewatersystemto
drain for 5 minutes.
3)Movethedispensemodeswitchtothe"CONTINUOUS"position,thendispenseallof
the ice from the storage bin.
Note: Ice dispenses continuously for a maximum of 60 seconds per activation.
4)Movethecontrolswitchtothe"OFF"position,thenturnoffthepowersupply.Remove
thefrontandtoppanels,thenmovethepowerswitchtothe"OFF"position.
5) Remove the storage bin cover. Remove spout B, then remove spout A.
6) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overow into the drain pan.
Note: If there is excess scale on the extruding head, ll the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block ow. Pour additional cleaning
solution over the extruding head until the evaporator assembly is completely full.
7) Replace spout A, spout B, and the storage bin cover in their correct positions.
8) Allow the icemaker to sit for 10 minutes before operation. If you placed a clamp on the
reservoir hose in step 6, remove it before operation.