Hoshizaki DCM-300BAH(-OS) Ice Maker User Manual


 
20
9) In bad or severe water conditions, clean the oat switch assembly as described below.
Otherwise, continue to step 10.
a. Remove the oat switch assembly from the reservoir cover.
b. Wipe down the oat switch assembly with the cleaning solution.
c. Rinse the oat switch assembly thoroughly with clean water.
d. Replace the oat switch assembly in its correct position.
10)Movethepowerswitchtothe"ON"positionandreplacethepanelsintheircorrect
positions.Turnonthepowersupply,thenmovethecontrolswitchtothe"ICE"position.
Make ice using the solution until the icemaker stops making ice.
Note: This unit will not run if the safety switch is not engaged.
11)Movethecontrolswitchtothe"DRAIN"position.Allowthewatersystemtodrainfor
5minutes.
12)Movethecontrolswitchtothe"ICE"position.Opentheicemakerwatersupplyline
shut-off valve to supply water to the reservoir.
13)Afterthegearmotorstarts,movethecontrolswitchtothe"DRAIN"position.Allowthe
water system to drain for 5minutes.
Note:Ifyoudonotsanitizetheunit,movethecontrolswitchtothe"ICE"positionafter
the water system drains. Allow the icemaker to run for 30 minutes, then move the
controlswitchtothe"OFF"position.Turnoffthepowersupply,thenremovethe
frontpanelandstoragebincover.Movethepowerswitchtothe"OFF"position.
Gotostep12in"III.A.2.c)CleaningandSanitizingProcedure"under"Dispensing
Components."
14)Movethecontrolswitchtothe"OFF"position,thenturnoffthepowersupply.
15) Close the icemaker water supply line shut-off valve.
c) Sanitizing Solution
Dilute 0.82 . oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with
1.6 gal. (6.0 l) of warm water.
d) Sanitizing Procedure - Following Cleaning Procedure
1)Makesurethecontrolswitchisinthe"OFF"position,thepowersupplyisoff,andthe
icemaker water supply line shut-off valve is closed.
2)Removethefrontandtoppanels,thenmovethepowerswitchtothe"OFF"position.
3) Remove the storage bin cover. Remove spout B, then remove spout A.
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overow into the drain pan.
5) Replace spout A, spout B, and the storage bin cover in their correct positions.
6) Allow the icemaker to sit for 10 minutes before operation.
7)Movethepowerswitchtothe"ON"positionandreplacethepanelsintheircorrect
positions.Turnonthepowersupply,thenmovethecontrolswitchtothe"ICE"position.
Make ice using the solution until the icemaker stops making ice.
8)Movethecontrolswitchtothe"DRAIN"position.Allowthewatersystemtodrainfor
5minutes.