Cornelius IWC330 Ice Maker User Manual


 
2
166240004
12/1/94
Rev 3/4/96
REMOTE CONDENSER SPECIFICATION
MODEL CR800 CR1200 CR1400
Volts 208/230 208/230 208/230
Phase 1 1 1
Hertz 60 60 60
Amps 1.0 1.0 1.0
Output, HP 1/6 1/6 1/6
Max. fuse size, Amps (HVAC circuit breaker
required)
20 20 20
ICE CUBER SPECIFICATION
MODEL
IAC322/330
IAC227
IWC322/330
IWCS227
IAC522/530 IWC522/530
UNIT
Volts 115 115 115 115
Phase 1 1 1 1
Hertz 60 60 60 60
No. Wires 2+ground 2+ground 2+ground 2+ground
MIN. CIRCUIT
Amps 20 20 20 20
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps 20 20 20 20
REFRIGERANT
Type R404A (HP62) R404A (HP62) R404A (HP62) R404A (HP 62)
Weight (oz) 17 15 26 23
Weight (g) 482 425 737 652
COMPRESSOR
Volts 115 115 115 115
Phase 1 1 1 1
Hertz 60 60 60 60
LRA 51 51 59 59
RLA 11.5 11.5 11.6 11.6
CONDENSER FAN MOTOR (Air-Cooled Systems only) of
AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)
Volts 115 115 115 115
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 1.7 0.38 1.75 0.38
Watts 50 6 50 6
WATER PUMP
Volts 115 115 115 115
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 0.88 0.88 0.76 0.88
HP 1/40 1/40 1/40 1/40