Jackson AJ-44 Dishwasher User Manual


 
AJ-44C Series Technical Manual 7610-001-76-22
Issued: 03-21-2006 Revised: 05-03-2007
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
CHANGING DUAL SANITIZATION MODE
48
Figure 2
Figure 1: Drive Mechanism
MODEL: AJ-44CE
SERIAL #
60 HZ 3 PHASE 3 WIRE
2.0 HPWASH MOTOR
CONVEYOR SPEED
WASH TANK TEMPERATURE160° F MIN.
460 V
2.8 A
1/4 HPDRIVE MOTOR 0.6 A
15 KWWASH HEATER LOAD 18.8 A
TOTAL AMP LOAD 22.2 A
FINAL RINSE TEMPERATURE
180° F MIN.
FLOW PRESSURE 20 5 PSI
±
HOT WATER
SANITIZING
6.9 FPM
CHEMICAL
SANITIZING
6.5 FPM
140° F MIN.
140° F MIN.
20 5 PSI
±
230 V
5.6 A
1.1 A
37.7 A
44.4 A
208 V
5.6 A
1.1 A
41.7 A
48.4 A
An Company
Commercial
Dishwasher
597G
NOTE: SEE INSTRUCTION IN MANUA
L FOR MODIFYING MODE OF
SANITIZATION.
US Patent Number(s):
6,012,567
Canadian Patent Number(s):
2,205,331
Made in the USA
Jackson MSC Inc.
P. O. Box 1060
Barbourville, KY. 40906
(606) 523-9795
09905-021-70-81 E
XXX XXXX X
If the machine has a dataplate like the one shown, which indi-
cates both Hot Water Sanitizing and Chemical Sanitizing
operation parameters (the area within dashed box), it is pos-
sible to change the sanitizing mode after the machine has left
the original manufacturer's facility. This change can only be
performed by an authorized Jackson service technician. If the
machine does not have a dataplate like the one shown, the
sanitization mode CAN NOT be changed.
Follow the instructions below to change the mode of sanitiza-
tion. Failure to follow these instructions can result in a viola-
tion of applicable regulatory codes.
DRIVE MECHANISM MAXIMUM SPEED ADJUSTMENT:
Note: This adjustment is only required when changing from
hot water sanitizing to chemical sanitizing mode.
Locate the maximum speed adjustment mechanism at the top
of the conveyor drive mechanism (Figure 1). Figure 2 shows
an enlarged view of the maximum speed adjustment mecha-
nism. Loosen the Bottom Jam Nut approximately one turn
counterclockwise. Move the Top Jam Nut down on the
threaded shaft by turning it approximately 1/2 turn counter-
clockwise. Tighten the Adjustment Nut by turning it clockwise.
Retighten the Bottom Jam Nut against the Top Jam Nut.
Bottom Jam Nut
Top Jam Nut
Adjustment Nut
Please note the parameters for both modes of sanitization. If your data
plate has this information, it is convertible from one mode to another.
XXXXXXXXX