Oven Sensor, Meat Probe and Cooling Fan Temperature Charts
OVEN SENSOR
Sensor Type: RTD 1000 platinum
Calibration: 1654 (350° F / 177° C)
Temperature F (C) Resistance (Ohms)
100 (38) 1143
200 (94) 1350
300 (149) 1553
350 (177) 1654
400 (204) 1753
500 (260) 1949
600 (316) 2142
700 (371) 2331
800 (427) 2516
900 (483) 2697
1000 (538) 2874
MEAT PROBE
Type: NTC Thermistor
Calibration: 9938 (150° F / 65.5° C)
Temperature F (C) Resistance (Ohms)
32 (0) 163300
68 (20) 62450
95 (35) 32660
122 (50) 18020
158 (70) 8760
185 (85) 5360
212 (100) 3400
COOLING FAN TEMPERATURES
MODE FAN ON TEMP F (C) FAN OFF TEMP F (C)
Bake 350 (177) 300 (149)
Broil
Six (6) minute delay
after cycle started
225 (107)
Clean
Six (6) minute delay
after cycle started
225 (107)