12
Alarm signal reset
• Stop the motor and switch off the lights.
• Press button T3 for at least 3 seconds, until the LEDs
start to flash.
Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
Charcoal filters
In the recirculation mode the charcoal filters absorb
smells and unwanted odours.
This charcoal filters cannot be washed or regenerated,
and must be replaced when the LED S1 starts to flash,
or at least once every 4 months. The alarm is only trig-
gered when the motor is on.
Enabling/Disabling the alarm
signal
• In Recirculation Version Hoods, the Filter saturation Alarm
must be enabled at the time of installation or later.
• Switch off the lights and the motor.
• Disconnect the mains power supply to the hood by
removing the motor unit power supply cable connector,
switching off the power supply at the Mains or turning
the Main switch off.
• Restore the connection, pressing and holding T1.
• Release the button. All five LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 flash
in confirmation:
• LED flashes twice - Activated charcoal filter saturation
alarm ENABLED
• LED flashes once - Activated charcoal filter saturation
alarm DISABLED
To Remove/Replace the char-
coal filters
• Disconnect by pulling only the central ducting panels.
• First remove the metal grease filters.
• Remove the saturated charcoal filter as shown in the
drawing (A)
• Position the new charcoal filter as shown in the drawing
(B).
• Replace the metal grease filters.
• Close the ducting panels.
A
B