Kenmore 795.7105 Refrigerator User Manual


 
INSTALLATION INSTRUCTIONS
Install the shutoff valve on the nearest frequently
used drinking water line.
1. SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure
on the line.
2. CHOOSE THE VALVE LOCATION
Choose a location for the valve
that is easily accessible. It is best
to connect into the side of a
vertical water pipe. When it is
necessary to connect into a
horizontal water pipe, make the
connection to the top or side, rather than at the
bottom, to avoid drawing off any sediment from
the water pipe.
3. DRILL THE HOLE FOR THE VALVE
Drill a 1/4" hole in the water
pipe using a sharp bit. Remove 1_1
any burrs resulting from drilling J_ I
the hole in the pipe. Take care _ I
not to allow water to drain into J_Y 1 I
the drill. Failure to drill a 1/4"
hole may result in reduced ice production or
smaller cubes.
NOTE: The hookup line cannot be white, plastic
tubing. Licensed plumbers must use only copper
tubing NDA tubing #49595 or 49599 or Cross
Link Polyethylene(PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
5. TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten or you may crush the
tubing.
Washer
Pipe Clamp __
Clamp Screw
Inlet End
6. ROUTE THE TUBING
Route the tubing between the cold water line and
the refrigerator.
Route the tubing through a hole drilled in the wall
or floor (behind the refrigerator or adjacent base
cabinet) as close to the wall as possible.
NOTE: Be sure there is sufficient extra tubing
(about 8 feet coiled into 3 turns of about 10"
diameter) to allow the refrigerator to move out
from the wall after installation.
7. CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve)
for copper tubing onto the end of the tubing and
connect it to the shutoff valve. Make sure the
tubing is fully inserted into the valve. Tighten the
compression nut securely.
Fasten the shutoff valve to the cold water pipe
with the pipe clamp.
Pipe Clamp
Saddle-Type
Shutoff Valve
Vertical Cold
Water Pipe
NOTE: Commonwealth of Massachusetts
Plumbing Codes 248CMR shall be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts. Consult with your licensed
plumber.
Saddle-Type ,,_
Shutoff Valve _
Packing Nut _
Outlet Valve
h
ession Nut
Ferrule (sleeve)
NOTE: Commonwealth of Massachusetts
Plumbing Codes 248CMR shall be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts. Consult with your licensed
plumber.
37