KitchenAid KESC307H Range User Manual


 
4-17
REMOVING THE MEAT PROBE JACK
1. Unplug range or disconnect power.
2. Open the oven door and remove the racks
from inside the oven.
3. Pull the range away from the wall so that
you can access the left side of the unit.
4. Remove the left side panel (see page 4-19
for the procedure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
7. Remove the metal sleeve and disconnect
the wires from the meat probe jack termi-
nals, then remove the jack from the unit.
Meat Probe Jack
5. Lift the spring-loaded cap on the meat
probe jack.
Meat Probe Cap
6. Use a 16mm socket and remove the meat
probe jack nut and felt washer from the
oven liner.
16mm Socket
Metal Sleeve
Violet & Red Wires
Meat Probe Jack