KitchenAid KUD01 Dishwasher User Manual


 
1
SECTION ONE
INSTALLATION CONSIDERATIONS
GENERAL CONSIDERATIONS
For complete installation procedures see the “Installation Instructions” in the
literature packet provided with the dishwasher.
A video presentation,
Key Features and Installation Considerations
, part number
4317280V, is available. This video covers the entire installation process.
Each location will present a different set of challenges that can be anticipated and solved before
installation begins.
Check the planned location of the dishwasher.
Easy access to hot water, drain line and electricity.
Convenient access for loading. The dishwasher door should open and close freely.
The opening under the counter should be square and the cabinet fronts should be perpendicu-
lar to the floor.
Make sure the cabinet opening is free of intrusions such as braces or utility lines.
Do not install the dishwasher on carpeted floors.
An outside wall behind the dishwasher should be insulated to prevent the water line, inlet valve
and drain line from freezing and rupturing.
The application of a horizontal pump and filter
technology allows for the tub to be designed three
inches deeper than current models. This deeper
tub and longer door design will impact the instal-
lation process because there is less working
space available underneath the unit and correct
routing and placement of the drain hose, water
supply and electrical wiring is critical.
The tub must be level. Reduced water consump-
tion of this dishwasher requires that it be installed
level and plumb for proper water recirculation back
into the sump area during operation.
Do not remove the drain
tube from the left side of
the tub. If the loop is
removed, the dishwasher
will not initiate Automatic
Purge Filtration. The drain
tube also contains a check
valve in the L-connector that
prevents backflow of water into
the dishwasher from the house-
hold drain system.
Drain Tube
Loop
Main Wash Motor
Drain Pump
Motor
Additional Considerations
44
SPECIFICATIONS
ELECTRICAL SUPPLY: (Under Load) 60Hz, 120VAC
SUPPLY WATER FLOW RATE: (To Fill 2 Quarts (1.9 L) in 27 secs.) - 120psi Max., 20psi MIN.
SUPPLY WATER TEMPERATURE: 120° F to 160° F (49° C to 71° C)
WATER CHARGE: 1.8 Gal. (6.8 L) / First Fill
1.7 Gal. (6.5 L) / All Other Fills
LOWER SPRAY ARM ROTATION: 25 TO 40 RPM
UPPER SPRAY ARM ROTATION: 25 TO 35 RPM
APF DRAIN: .1 Gal. (.38 L) per 5 sec.
APF Pressure Switch Trip Point: 10 In. Water Column
HEATING ELEMENT HEATING RATE: 1°+ F Rise per Minute
Baked On Cookware Heavy, Normal
WATER USAGE
Soil Level
Sensed
Water
Usage
(gal/L)
High
Low
8.8 -10.4/
33.4 -39.4
6.9/
26.2
China - Light/China
Quick Clean Up
Soil Level
Sensed
Water
Usage
(gal/L)
High
Low
7.1-8.6/
26.9-32.5
5.5/
20.8
6.9-8.4/
26.1-31.8
5.2-6.7/
19.7-25.4
First Fill
Water
Temp
Water
Usage
(gal/L)
Less
than
135° F
(57° C)
Greater
than
135° F
(57° C)
Water
Usage
1.8-2.1/
6.9-7.9
Rinse Only
View of Sump Assembly from Underneath
Showing Horizontal Wash Pump Motor
and Drain Pump Motor