11
Icemaker
Figure 16
Figure 17
9. Open the shut-off valve for the water supply and
check the entire water system for leaks.
IMPORTANT
After starting up the appliance, the water pipe
system must be purged of any air. Refer
to chapter "Bleeding the ice maker" in the
operating instructions.
Figure 15
Anti - tipping bracket
Compressor mounting
plate
Wall
Appliance
4. Push the appliance slowly to the back wall until
the compressor mounting plate makes contact
with the anti-tipping bracket (Figure 15).
To prevent the appliance from tipping
forward the compressor mounting plate
must have contact with the anti tipping
bracket (Figure 15).
5. Remove the cover from the valve connector
(Figure 16).
6. The water line is visible at the front of the
aplliance. Connect the water line with the OD
adapter (Figure 16).
7. Bleed the air from the water line by opening the
water supply temporarily.
8. Screw the OD adapter onto the solenoid valve
(Figure 17).