Liebherr HC 2062 Refrigerator User Manual


 
Cabinet Opening Dimensions - Figure 4
Figure 4
IMPORTANT
Do not install the shut-off
valve behind the appliance.
IMPORTANT
The free length of the water supply line must be at least
31-1/2" (800 mm) when the tube comes out of the pre-
scribed opening.
IMPORTANT
For 24" cabinets, the water line opening must be in the
location as shown in Figure 4.
With cabinets deeper than 24", there is room to fit the
pipe behind the appliance and the wall so there are no
requirements for the water line lead out position.
Cabinet
Height C
Inset cabinet
Depth B
Frameless/faceframe cabinet
Depth B
80" 24" + panel thickness 24"
84" 24" + panel thickness 24"
Water line opening
Water supply line
The position of the electri-
cal outlet is possible within
the grey shaded areas or
above the appliance.
For appliance with panel to be
flush, adjacent cabinetry depth
must equal appliance depth (24")
plus panel thickness (5/8" - 3/4").
5
plannInG InformatIon