Manitowoc Ice 11M Refrigerator User Manual


 
Installation Section 2
2-6
Part Number 020001552 5/11
Installer Instructions
These equipment instructions are intended to assist
qualified personnel in the unpacking, locating and the
initial operation of the Multiplex Beverage Equipment
Post Mix Refrigeration Unit.
PREPARATION
The Multiplex Beverage Equipment Post Mix
Refrigeration Unit is pre-assembled in the factory and
requires minimum installation.
For future reference or to be used when ordering parts,
record the Model Number, Serial Number, Part Numbers
of Unit, Condenser (if remote), Towers, etc., and Date of
Installation on the inside of this Manual. Leave manual
on site in a safe place. Do not discard manual.
Ambient Location Requirement
This equipment is rated for indoor use only. It will not
operate in sub-freezing temperature. In a situation when
temperatures drop below freezing, the equipment must
be turned off immediately and properly winterized.
Contact the manufacturer for winterization process.
Electrical
GENERAL
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the beverage/ice machine’s running amp
load.) The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for
voltage/amperage specifications.
SPECIFICATIONS
Important
The remainder of these instructions is to be
completed by an authorized Multiplex Installer.
Important
This publication must be saved for future reference.
Read instructions before attempting installation.
!
Warning
All wiring must conform to local, state and national
codes.
Model Volt/Cycle/Phase Minimum Circuit Amps Breaker Compressor
11M 120/60/1
230/50/1
21.5
10.7
30A
16A
1/2 hp
.97 kW